215KWH All In One Liquid Cooling Lithium Ion Battery Energy System 0.5C

  • Liquid cooling
  • Easy installation,operation and maintenance
  • User-Friendly
  • Seamless switching
  • Long operationg life,support full power charge and discharge
  • Safe and reliable
  • Flexible configuration
  • MPPT optional: according to the actual demand
  • Wind power storage
  • Optical storage
  • Off-Grid island
  • Nomadic farm
  • Off-Grid Mine
  • PV station + ESS
  • Villages without electricity

Product Specifications

Technical specification for 2 hour backup(0.5C)

MODEL 100KW-215KWH 100KW-232KWH 125KW-241KWH 125KW-252KWH 125KW-261KWH
DC(Battery)
Cells Type LiFePO4 Lithium Iron Phosphate
Cell specfication 3.2V280Ah 3.2V280Ah 3.2V314Ah 3.2V304Ah 3.2V314Ah
Configuration of Battery 240S1P 260S1P 240S1P 260S1P 260S1P
Single Battery Pack 153.6V280Ah/43.008kWh 166.4V280Ah/46.592kWh 153.6V314Ah/48.230kWh 166.4V304Ah/50.586kWh 166.4V314Ah/52.250kWh
Battery Module 5 Packs 5 Packs 5 Packs 5 Packs 5 Packs
Battery Capacity 215kWh 232kWh 241kWh 252kWh 261kWh
Max. Power 100KW 100KW 100KW 100KW 100KW
Max. Current 140A 140A 157A 152A 157A
Battery Rated Voltage 768V 832V 768V 832V 832V
Battery Voltage Range 672V-864V 728V-936V 672V-864V 728V-936V 728V-936V
AC(On / Off Grid)
Max. Power(kVA) 110KVA 137KVA
Active Power(kW) 100KW 125KW
Rated Voltage(V) 400V 400V
Rated Current(A) 144A 180A
Voltage Range 320V-460V 320V-460V
Rated Frequency 50/60Hz 50/60Hz
Range of Frequency 45-55/55-65Hz 45-55/55-65Hz
THDI <3% <3%
Power factor 1.0(Adjustable from 0.8 leading to 0.8 lagging) 1.0(Adjustable from 0.8 leading to 0.8 lagging)
AC System 3 phase 4 wires 3 phase 4 wires
Overload capability 110% 110%
Solar Side(PV) Optional
Max. Power 100KW(50KW*2)
High Volage side Voltage 560V-1000V
High Voltage side Current 160A
Low Voltage side Voltage 500V-900V
Low Voltage side Voltage 200A
Uninterrupted Load(STS)) Optional
STS Power 200KW
STS Voltage 400V 50HZ/60HZ
Overload Power 110%
Shift Time <20mS
System operation stratege
Functional Anti Backflow and Black Start
Operation Mode Selections Power peak shaving and valley filling, electricity price peak valley arbitrage,
photovoltaic priority for electricity cost savings, wind power generation
priority for electricity cost savings, off grid power supply for remote areas
Scenerios Photovaltaic and diesel storage project, Wind power and diesel storage project, Wind and photovoltaic
diesel storage project, Charging Station + Energy storage project, On-grid electricity selling project
Specificaiton
Cabinet Size(W*D*H) 1585/1366/2055mm
Weight ≤2.7 T
Max. cycle efficiency ≥ 90 %
IP rating IP55
Auxiliary Power Supply Self-powered, Externally powered
Corrosion resistance rating C3/C5
Operating Humidity Range 0%-100%(Non-condensing)
Operating Temperature -30℃-50℃(>45℃ derating)
Max. Operation Altitude 2000 m
Communication: Ethernet、485、CAN
Communication Protocal ModbusTCP
Cooling method Intelligency Liquid Cooling
Fire safety configuration Smoke detector, Heat detector, Gas-based fire extinguishing system, Pressure relief valve, Pack-level fire protection, Cluster-level fire protection, Water-based fire protection, Automoatic pressure relief